HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\WebLink\Published Locations\<ID>
Value Name | Data Type | Value Data |
---|---|---|
CheckCredentials |
DWORD | If this value is 1, explicit user authentication is required to open a vault. If 0 (default), the current Windows account is used and separate authentication is not necessary. This setting corresponds to the Authenticate logon credentials with the operating system option on the Authentication tab of the Vault Settings page of the Environment branch in Meridian Enterprise Configurator. |
CollectExisting |
DWORD |
If this value is 1, the Value list in the Find dialog box shows a list of the existing values in the vault for the selected property regardless of how the Select a value from option is set for that property in the vault configuration as described in Restricting user input. If 0 (default), no values are listed in the Find dialog box. If desired, set this value to 1 if all properties that are likely to be searched have manageable quantities of unique, existing values and the performance of showing the value lists is acceptable. The behavior of the value list on property pages is unchanged and reflects the configuration setting. This affects only PowerWeb, not PowerUser. |
CommonWorkspace | String | A value used to lock documents by all PowerWeb users from remote access client computers for this published location. |
Name |
String |
Name specified in Configurator for the published vault context. |
Scope |
String | Name of a scope to show for the location. |
StartPage |
String |
GUID of a global search query to set as default the default landing page. |
Vault |
String |
Vault context published by PowerWeb for use by Local Workspace. |
WorkspaceLockID | String |
A unique value that identifies a user's Local Workspace on each computer that they use. This value is only used by PowerWeb. For PowerUser, see the WorkspaceLockID value in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Client (for all users of the PC) and HKEY_CURRENT_USER\Software\Cyco\AutoManager Meridian\CurrentVersion\Client\Settings (for current user of the PC). For a pool of remote access host computers (running PowerWeb), see the CommonWorkspace value above. |