HKEY_CURRENT_USER\Software\Cyco\AutoManager Meridian\CurrentVersion\Client\Settings
- The following locations will be searched for this value in the order listed and the value of the first location where it is found will be applied :
- This registry key (affects only the current user of the PC).
- HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Client (affects all users of the PC)
Value Name | Data Type | Value Data |
---|---|---|
AssetManagementUseAdditionalFiltering |
DWORD |
If this value is 1, retired and inactive project copies are hidden in the Manage Tag Links dialog box of the Meridian Asset Management Module. This setting is overridden by the vault configuration as described in the Meridian Asset Management Module 2018 Administrator's Guide. |
AutoExpandOnDrag |
DWORD |
If this value is 1, causes folders to automatically expand when a document is dragged over them. If this value is 0 (default), the folders do not automatically expand. |
BCSiteCacheURL | String |
URL of the site cache server for use by PowerWeb. This setting overrides the same setting in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Client for the current user. Important!
Users should not work on the same documents from more than one PC with Application Integration in Remote mode and site caches enabled or document content inconsistencies can occur. |
BriefCaseCache |
DWORD |
Location of temporary folder for external format briefcases. If this value is not set (default), uses default temporary directory (%TEMP% environment variable). |
BriefCaseOpenFormat |
String |
Default briefcase metadata format created on 32-bit computers. The default is XML (always on 64-bit computers). Set this value to .mdb to store the metadata in Access format. |
ClientServerWebView |
DWORD |
If this value is 1, the client applications use the AutoVue Client/Server viewer. If this value is 0, the client applications use the locally installed viewers. |
ContextHelpEnabled |
DWORD |
If this value is 1, enables the context-sensitive Help in client applications. If this value is 0 (default), context-sensitive Help is cleared. |
CopyFiles |
DWORD |
If this value is 1 (default), enables Duplicator’s Copy Inventor drawings and… option. |
CreateThumbnailOn |
DWORD |
Sum of bit flags indicating when to update thumbnails. 1 On import |
dbgEnableScriptDebugger |
DWORD |
If this value is 0, do not display the Script Debugger item on the Tools menu of PowerUser. If this value is 1, show the Script Debugger item if a script debugger is installed. Configured in the PowerUser Options dialog. |
DebugMode |
DWORD |
Sum of bit flags that specify debug levels. For internal use only. |
DisableMenuWF |
DWORD |
If this value is 1, disables the Workflow menu in PowerUser. If this value is 0 (default), enables the menu. |
DisableNotFoundMessage |
DWORD | If this value is 1, an information message is not shown when a user attempts to navigate to a document that is outside of the scope of the current navigation view. The view is automatically set to the Explorer view. If this value is 0 (default), the message is shown and the user must dismiss the dialog box before the view is changed. |
DisableOfflineSwitch |
DWORD |
If this value is 1, disable Offline mode switch in Application Integration. If this value is 0 (default), do not disable Offline mode. See Disable Offline Mode. This value overrides the value with the same name in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Client. |
DisableVaultShortcuts |
DWORD |
If this value is 0 (default), the Create Shortcut to This Vault command is enabled. If this value is 1, the command is cleared for the current user. Note:
This setting must be 0 for the command to be enabled if a scope is active and the command is enabled for that scope. |
DisplayManualReferences |
DWORD |
If this value is 1 (default), enables inclusion of manual references in Assembly structure and Where used dialogs. |
DisplayValidationAlerts |
DWORD |
If this value is 1, show a warning when opening a document in a read-only workflow state. If this value is 0, do not show a warning. Configured in the PowerUser Options dialog. |
DoNotSyncLWS4ShellMenu |
DWORD |
If this value is 1, the Local Workspace copy of the selected document will not be synchronized before retrieving related shell menu items. If this value is 0 (default), the document is synchronized. |
FlagsFor64bitExtensions |
DWORD |
Controls the loading of custom extensions by 64-bit client applications. If this value is 0, do not restrict extension loading. If this value is 1, do not load extensions. If this value is 2 (default), load extensions. |
GrayTextColor |
DWORD |
If non-zero, Windows text color is used instead of standard (gray) color for cleared controls. On closing of PowerUser, this value is set back for dimmed controls. Default is 0. Important!
If this is set to anything but 0x808080, can affect other applications after PowerUser is closed. |
HighlightRecentDocs |
DWORD |
If this value is 1, highlight documents that are less than RecentDocsDateSpan days old. If this value is 0 (default), do not highlight. |
IncludeIntermediate | DWORD | If this value is 1 (default), enables the assembly duplicator’s Include connecting assemblies option in the Assembly Copy Options dialog box. |
LastReleasedColor |
DWORD |
Color to display last released document names in the Show Revisions dialog box. |
OfflineMode |
DWORD |
If this value is 1, use PowerWeb in offline mode. If this value is 0, do not use offline mode. This can also be set on the Application Integration shortcut menu. For use with remote access software, set this value to 1 on the remote access client PC and to 0 on the remote access host PC. This value overrides the value with the same name in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Client. |
QuickSearchAutoAppend |
DWORD |
If this value is 1 (default), enables the AutoComplete feature in Quick Find combo boxes. If this value is 0, the feature is cleared. |
RebuildDirectoryStructure |
DWORD |
If this value is 1, sets the assembly duplicator’s Folder structure option in the Assembly Copy Options dialog box to Rebuild folder structure relative to each sub assembly. If this value is 0 (default), sets it to Rebuild folder structure relative to the main assembly. |
RecentDocsDateSpan |
DWORD |
Age of documents in days to highlight. If this value is 0 (default), do not highlight. |
RedlinesWidth |
DWORD |
Width in pixels to display Meridian redlines in the Meridian viewer. Configured in the PowerUser Options dialog. |
ReleaseAllAssembly |
DWORD |
If this value is 0, release only the documents that are parts of a CAD assembly. If this value is 1, release the assembly documents and all other documents that are related by Meridian references. |
RowsToRetrieveForFind |
DWORD |
Maximum number of documents to show in Find results at one time. |
ShowAllTablesImportDB |
DWORD |
If this value is 0 (default) the Database Import Wizard in Meridian Enterprise Configurator will only show the tables of the type TABLE (named ranges) that are present in a Microsoft Excel worksheet for selection to import. If this value is 1, the tables of all types are shown. |
ShowRenditions |
DWORD |
Displays the rendition of the selected document in the viewer pane by default instead of the source file. This setting can also be configured in the PowerUser Options and PowerWeb Preferences dialogs. |
ThumbnailAutoUpdate |
DWORD |
If this value is 1 (default), enables automatic generation of thumbnails. If this value is 0, disables automatic generation. |
ThumbnailUpdateMode |
DWORD |
If this value is 1, generates thumbnails with viewer. If this value is 0 (default), use saved preview images when available. Configured in the PowerUser Options dialog. |
UpdateReferences |
DWORD |
If this value is 1 (default), enables the assembly duplicator’s ’s Update SolidWorks references option in the Assembly Copy Options dialog box. |
UseImportedFrom |
DWORD |
This setting overrides the server registry key with the same name described in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Server. |
UseWebHelp |
DWORD |
If this value is 0 (default), local help content is shown when the user presses F1 within a Meridian client application. If this value is 1, online webhelp content is shown. The location of the webhelp content is specified in the WebHelpBaseURL registry value described in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion. |
WebServicesMode |
DWORD |
If this value is 0 (default), Application Integration operates in Online mode. If this value is 1, it operates in Remote mode. This value overrides the value with the same name in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Client. |
WorkSpaceDB1 |
DWORD |
Local Workspace database format and version. Possible values are: 0 – Microsoft Jet database engine (default, installed separately) 1 – SQL Server Compact Edition 3.5 (installed separately) 4 – SQL Server Compact Edition 4 (installed separately) 8 – SQLite (installed only by the Meridian Cloud Client installation package) Note:
If you install the 64-bit edition client components on a remote access host computer, SQL Server Compact Edition must be installed in advance if it will be used. If the 32-bit edition client components are used on a 64-bit computer, SQL Server Compact Edition must be installed. In either case, if SQL Server Compact Edition is not used for the Local Workspace, the Meridian application links will not be available. |
WorkSpaceLockID1 |
String |
A unique value that identifies a user's Local Workspace on each computer that they use. This value is only used by PowerUser. For PowerWeb users, see the WorkspaceLockID value in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\WebLink\Published Locations\<ID> If a pool of remote access host computers (running PowerUser) will be used, set this to a value to be used by all of the remote access host computers, such as Citrix or RemoteDesktop. The value can be anything so long as it is the same for all of the remote access host computers. For remote access host computers running PowerWeb, see the CommonWorkspace value in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\WebLink\Published Locations\<ID>. |
WorkSpaceNoUserName1 |
DWORD |
If this value is 1, the user account name is not appended to the Local Workspace folder name. If this value is 0 (default), the account name will be appended. This is useful only if WorkSpaceLocation is also defined. If set in the HKEY_LOCAL_MACHINE hive on the Meridian web server for the account under which Application Integration runs, Application Integration will periodically clean up the local workspace location of all stale temporary files created for PowerWeb users. |
WorkingColor |
DWORD |
Color to display document names in the view pane for documents under change. |