In Vaults
with a large number of inactive Work Areas, opening the Vault or switching
between Work Areas can take a very long time. This time can be dramatically
improved by removing directories for inactive or empty Work Areas from
Local Workspace. This is now done automatically by IC2007 whenever the
Local Workspace is 'cleaned' (ie. the total size of LWS exceeds the set
maximum and unneeded files are removed). It is possible to force this
cleanup by setting the following registry setting: HKEY_CURRENT_USER\Software\Cyco\AutoManager Meridian\CurrentVersion\AMSync\Settings ForceClean (REG_DWORD), default is 0 (do not force clean-up) 24316 Performance problems with 2006B and
workareas 19832 Remove empty workspaces
When
a document is selected in the PowerUser, without opening, the file is
still being copied to Local Workspace. This can be prevented with the
following registry setting: HKEY_CURRENT_USER\Software\Cyco\AutoManager Meridian\CurrentVersion\Client\Settings DoNotSyncLWS4ShellMenu (DWORD), default is 0 (old behavior). Note that regardless of this setting documents will still be copied
as needed, therefore this setting will only have effect if the Viewer
is disabled. 24531 Document copied
to local workspace when you click the document (iso opening document)
The 'Start Quick Change for others' privilege was incorrectly
listed in the Configurator for AutoManager TeamWork while the corresponding
functionality is not available in TeamWork. This privilege is now removed.
19410 Teamwork::Create quickchange
for other is listed as a privilege
It is
now possible to drag-and-drop messages from Microsoft Outlook directly
in the InnoCielo Client. 22356 Make
Drag and Drop possible from outlook to AMM
When
using a navigation view other than the Explorer View in the Application
Integration it would be impossible to Create a Quick Change in that Application
Integration. This is now fixed. 22800
Cannot start quick change in AI in view other than explorer
Having
a memo in the list of properties to synchronize for an Office document
would break the entire property synchronization. This is now fixed. 23769 Writing to memo property in extension
breaks office property link
The
'Set Property Value...' command was not available for Retired documents.
This is now fixed. 23780 Property value
can't set to Retired documents
The
InnoCielo Client would sometimes come to front and re-claim focus after
opening a document from it. This would be most noticeable when a CAD application
was started for that document. 24562
slow machines will see poweruser getting focus instead of cad-documents
opened from the poweruser
The
duplicator dialogs (InnoCielo Derive and InnoCielo Replace) now correctly
update the 'Select for copy'/'Use original' status for parts that occur
multiple times in an assembly. 16646
Check consistency of selected items in Duplicator dialog
It was impossible to create multiple sub-parts
on a hybrid document without renaming these parts in between. This is
now fixed. 16995 It's impossible to
create more then 1 part for hybrid document