New in AM2005a: Limiting Client Usage
It is now possible to limit
the load on the EDM Server that is caused by the PowerUser and OfficeClient,
by defining a maximum number of instances for each workstation, and a
period of inactivity after which the server connections are closed. These
settings need to be set in each workstation's registry. By default the
number of instances and time-out are not limited.
- HKEY_LOCAL_MACHINE\SOFTWARE\Cyco\AutoManager
Meridian\CurrentVersion\Client
DWORD PowerUser_MaxInstances
Defines the maximum number of PowerUser instances that can be open
simultaneously.
- HKEY_LOCAL_MACHINE\SOFTWARE\Cyco\AutoManager
Meridian\CurrentVersion\Client
DWORD OfficeClient_MaxInstances
Defines the maximum number of OfficeClient instances that can be open
simultaneously.
- HKEY_LOCAL_MACHINE\SOFTWARE\Cyco\AutoManager
Meridian\CurrentVersion\Client
DWORD MinutesToSleep
Defines the number of minutes of inactivity after which a PowerUser
or OfficeClient will automatically close the connections to the EDM server.