If you
want to use this registry key, add the following DWORD registry value
under
HKLM\SOFTWARE\Cyco\<Active Product>\CurrentVersion\AMHookTray
on the client machine: "DisableAIMenu"=dword:00000001.
- When
doing "Save As" in AutoCAD 2004, "Out of memory" error
message appeared for certain vault configurations, which were using AutoPages
functionality. This is now fixed.
- When
creating Inventor document through Application Integration, the Inventor
Link did not perform property update from the vault to the Inventor file.
This is now improved and the Inventor Link makes property update in this
case.
- When
using Local Workspace for working with MicroStation drawings, in the situation
when submitted X-Ref is moved to another folder (for example, after changing
a FPR property of this document) it is present both in old and new locations
in Local Workspace cache. MicroStation link was resolving this X-Ref from
the old location, deleting also AMDocRef object to this X-Ref. This is
now changed in AutoManager 2003d so that this X-Ref is resolved correctly
in this situation.
- The
"AutoManager Derive" function in the Inventor Link worked incorrectly
for a parts with an outgoing reference to an Excel sheet. This has been
resolved.
- The
"AutoManager Derive" function in the Inventor Link worked incorrectly
for a parts or assemblies with an incoming reference from an IDW or IPN
file. This has been resolved.
- When
using the Assembly Import Tool for importing an Inventor Assembly, the
Assembly Import Tool locked imported documents even if Local Workspace
was not in use for the current vault. This is improved in AutoManager
2003d so that the Assembly Import Tool does not lock imported documents
anymore.
- When
using the Assembly Import Tool for importing a SolidWorks Assembly, if
SolidWorks was already started before running the Assembly Import Tool,
it was closed after Assembly Import Tool was finished. This is now improved
and SolidWorks is not closed in this situation anymore.
- When
doing AutoMananger Replace, there was no confirmation dialog. It is improved
now and the confirmation message "Are you sure you want to replace
the selected component with the most recent replacement?" is shown.
- When
using "Go to last document" functionality in Application Integration
for the large vaults with a deep subfolder structure, this resulted in
significant performance problem (delays). It was not possible to make
this "Go to last document" optional. It is improved now in AutoManager
2003d - new registry keys are introduced, which control this functionality:
HKEY_CURRENT_USER\Software\Cyco\<Active
Product>\CurrentVersion\AMHook\Settings
FindLastObjectOnOpen
DWORD, default is 1
FindLastObjectOnView
DWORD, default is 1
To disable this functionality
you should set 0 for an appropriate registry key.