BlueCielo TeamWork 2012 Administrator's Guide | BlueCielo ECM Solutions |
Value Name |
Data Type |
Value Data |
CacheLockOnOpen |
DWORD |
If this value is >0, forces the link to set cache lock on every document in an assembly that is currently under change by the user. If this value is 0, does not set cache lock. |
CompactOnUpdate |
DWORD |
If this value is >0, forces purging of backup copies upon saving file. If this value is 0, does not purge. Used by Inventor versions older than 6.0. |
CreatesQuickChange |
DWORD |
If this value is >0, forces the link to use Quick Change instead of Under Change. If this value is 0, does not use Quick Change. |
HideGetWriteAccess |
DWORD |
If this value is 1, hides messages by clicking No. If this value is 2, hides message by clicking Yes. If this value is 0, does not hide messages. |
HideIsReadOnlyMessage |
DWORD |
If this value is >0, disables messages about the document being read-only. If this value is 0, enables messages. |
NewLibraryComponentDocType |
String |
Document type internal name to use for any new library document created by Inventor. |
NumberOfVersionsKept |
DWORD |
Number of backup copies to keep. Used by Inventor versions older than 6.0. |
OnSaveTimeOut |
DWORD |
Max time (in msec) to wait for AMFS to complete when saving file. Default = 0. Obsolete. |
RedrawTitleblocksOnUpdate |
DWORD |
If this value is >0, enables regeneration of title blocks after properties update to file. If this value is 0, disables regeneration. |
ReleaseNewLibraryComponent |
DWORD |
If this value is >0, forces the link to release a library component after it has been imported into the vault. If this value is 0, does not release. Use with NewLibraryComponentDocType. |
SettingsSource |
DWORD |
If this value is 1 (default), the following settings are read from the Inventor application link settings configured in Configurator. If this value is 0, these settings are read from the registry of the client computer: HideIsReadOnlyMsg |
ShowAMBrowserOnOpen |
DWORD |
If this value is 0 (default), the Inventor browser will be activated upon file open commands. If this value is >0, the TeamWork Assembly Browser will be activated. |
ShowOptionsOnOpen | DWORD | If this value is 1 , the Inventor File Open Options dialog will be shown when opening assemblies. If this value is 0 (default), the dialog is not shown. |
ShowOptionsOnSave | DWORD | If this value is 1 , an Options button is added to the Inventor Save Copy As dialog and File Save Options dialog. Users may click this button to show the Inventor File Save Options dialog when saving assemblies. If this value is 0 (default), the button is not shown. |
SupportInventorDWG |
DWORD |
If this value is 0 (default), Only AutoCAD drawings are supported. Autodesk Inventor drawings are not supported. If this value is 1, AutoCAD drawings are not supported. Only Autodesk Inventor drawings are supported. If this value is 2 or any other value, Both Autodesk Inventor and AutoCAD drawings are supported, but errors can occur if the applications use different versions of RealDWG on the same computer. |
TerminateInventor11 |
DWORD |
If this value is 1, activates a workaround that solves a problem related to Inventor 11 Automation Server. If this value is 0 (default), does not activate the workaround. |
UpdateDWFForAll |
DWORD |
If this value is >0, the Inventor Link will generate DWF images for any modified files when saving. If this value is 0 (default), a DWF file for only the main document is generated. |
UpdateDWFOnSave |
DWORD |
If this value is >0, the Inventor Link will generate a DWF image when saving a file. The DWF file is imported into the vault (if possible) as a hybrid part of the saved document. If this value is 0 (default), no DWF is generated. |
Copyright © 2000-2012 BlueCielo ECM Solutions |